All manuals and user guides at all-guides.com INSTRUCTIONS GE Industrial Systems GE Industrial Systems D8R4 expanded I/O for AV-300i Drives 8 Digital Inputs 4 Relay Outputs...
Page 2
If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the matter should be referred to GE Industrial Systems, Salem, Virginia, USA. This document contains proprietary information of...
Page 3
D8R4 expanded I/O All manuals and user guides at all-guides.com SAFETY SYMBOL LEGEND / LÉGENDE DES SIGNES DE SÉCURITÉ ARNING Commands attention to an operating procedure, practice, condition, or statement which, if not strictly observed, could result in personal injury or death.
Page 4
GEI-100425A All manuals and user guides at all-guides.com —————— I/O Expansion card ——————...
Page 5
D8R4 expanded I/O All manuals and user guides at all-guides.com Table of Contents SAFETY SYMBOL LEGEND / LÉGENDE DES SIGNES DE SÉCURITÉ ................3 Chapter 0 - SAFETY PRECAUTIONS / PRECAUTIONS DE SECURITÉ ................6 Chapter 1 - INTRODUCTION ............. 12 Chapter 2 - MOUNTING ............
Page 6
GEI-100425A All manuals and user guides at all-guides.com Chapter 0 - SAFETY PRECAUTIONS / PRECAUTIONS DE SECURITÉ The terms “Inverter”, “Controller” and “Drive” are sometimes used interchangably throughout the indus- try. We will use the term “Drive” in this document Les mots “Inverter”, “Controller”...
Page 7
D8R4 expanded I/O All manuals and user guides at all-guides.com 89/392/EEC concernant le secteur de l’industrie. Les systèmes provoquent des mouvements mécaniques. L’utilisateur est responsable de la sécurité concernant les mouvements mécaniques. Les dispositifs de sécurité prévues par l’usine et les limitations operationelles ne doivent être dépassés ou modifiés.
Page 8
GEI-100425A All manuals and user guides at all-guides.com Drives should be installed away from hazardous areas, even if used with motors suitable for use in these locations. L’utilisation des drives dans des zônes à risques (présence de vapeurs ou de poussières inflammables), peut provoquer des incendies ou des explosions.
Page 9
D8R4 expanded I/O All manuals and user guides at all-guides.com ! / P AUTION RECAUTION Do not connect power supply voltage that exceeds the standard specification voltage fluctuation permissible. If excessive voltage is applied to the Drive, damage to the internal components will result.
Page 10
GEI-100425A All manuals and user guides at all-guides.com A capacitative load (e.g. Var compensation capacitors) should not be con- nected to the output of the frequency inverter (terminals U2, V2, W2). The electrical commissioning should only be carried out by qualified per- sonnel, who are also responsible for the provision of a suitable ground connection and a protected power supply feeder in accordance with the local and national regulations.
Page 11
D8R4 expanded I/O All manuals and user guides at all-guides.com d’enlever des matériaux isolants ou des capots. Protéger l’appareil contre des effets extérieurs non permis (température, humidité, chocs etc.). Aucune tension ne doit être appliquée sur la sortie du convertisseur (bornes U2, V2 et W2).
Page 12
GEI-100425A All manuals and user guides at all-guides.com Chapter 1 - INTRODUCTION The D8R4 card adds digital Inputs and relay outputs to the drive. It is possible to use only one I/O expansion card per Drive. This option card features: 8 optocoupled digital inputs 15V up to 30VDC 4 relay outputs with 250V max dry contact, 1 N.O.- 1N.C.
Page 13
D8R4 expanded I/O All manuals and user guides at all-guides.com Chapter 2 - MOUNTING The D8R4 card is supplied with standoffs and the cable for connection between regulation and expansion card . Switch the drive off. Fasten the D8R4 card to the drive regulation board by means of screws (B) and standoffs (A).
Page 14
GEI-100425A All manuals and user guides at all-guides.com Chapter 3 - TERMINAL BOARD POINTS 3.1 DIGITAL INPUTS TERMINAL BOARD POINTS Connectors XDI0 and XDI1 have different ground connection. DIGITAL INPUTS Connector XDI0 Terminal Function (Fw 1.X ) Digital input 5 Digital input 6 Digital input 7 Digital input 8 GND Function (Fw 2.X ) DI0X DI1X...
Page 15
D8R4 expanded I/O All manuals and user guides at all-guides.com RELAY OUTPUTS POWER SUPPLY Connector Terminal Function 0V power supply +24V power supply exp30 3.3 FUNCTIONAL OVERVIEW +24V Digital input 5 POWER SUPPLY (DI0X) 0V (COM) CONNECTOR XSC Digital input 6 (DI1X) N.Closed...
Page 16
GEI-100425A All manuals and user guides at all-guides.com I/O available depending on drive firmware version Drive firmware from 2.X Digital Inputs Relay Outputs Digital Inputs & Relay Outputs setting EXP-board terminals Drive firmware setting Drive firmware setting Digital input 5 DI0X Digital input 6 DI1X...
Page 17
D8R4 expanded I/O All manuals and user guides at all-guides.com Chapter 4 - TECHNICAL DATA Dimensions and Weight 118 mm (4.6”) Dimensions ________________________________ 118 mm [4.6 inches] x 92 mm [3.6 inches] Weight _____________________________________ 113 g [ 4 oz] —————— I/O Expansion card ——————...
Page 18
GEI-100425A All manuals and user guides at all-guides.com General Data I/O Scan time _______________________________ 2ms Internal power supply from the drive ____________ +5V Digital Inputs Input type _________________________________ Voltage/Optocoupled Inputs no. __________________________________ 8 (2 groups of 4 inputs) 0V connection _______________________________ different 0V for the groups Voltage input value ___________________________ 15 up to 30V Current input value ___________________________ 4.5 up to 9mA Relay Outputs...
Page 19
D8R4 expanded I/O All manuals and user guides at all-guides.com Chapter 5 - ACCESSORIES Terminals XCQ0,XCQ1 ____________________ Type PHOENIX CONTACT 6 contacts MSTB2, 5/ 6 ST5,08 1757051 Type WIELAND 6 contacts 25.340.3653.0 Terminals XDI0,XDI1 _____________________ Type PHOENIX CONTACT 5 contacts MC1,5/5 ST3,81 1803604 or equivalent.