Transport and handling conditions
The unit should be handled gently and sudden movements should be avoided. Ensure that the place where it is to be stored or used is
carefully prepared beforehand. Before any fixed installation on a trailer or inside a vehicle, consult one of our approved agents.
Before transporting the unit, take the following necessary precautions:
1.
Check that the routes to be used are smooth and drivable. If it proves necessary to use uneven roads, drain the fuel into a
container before setting off.
2.
Check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the battery (if fitted).
3.
The unit should always be transported in its normal operating position; never lay it on its side. Ensure that the unit cannot
fall from the vehicle carrying it, but without exerting too much force (risk of damaging the unit).
6.2
Storage conditions
This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
Drain the fuel and change the engine oil:
1.
For units equipped with a noise deflector (A4), swivel this forward.
2.
Start the unit and allow it to operate until it runs out of fuel.
3.
Set the switch to OFF (A7).
4.
Clean the sediment bowl (A11-C2).
5.
Close the fuel tap (A5).
6.
Top up the oil.
Grease the cylinder and valves:
7.
Remove the spark plug (A13-F2) then, via its aperture, pour in approx. one teaspoon of new engine oil.
8.
Refit a new spark plug in its place.
9.
Pull the starter-recoil reel handle (A8) several times to distribute the oil inside the cylinder.
Storing the unit:
10. For units equipped with a noise deflector, return it to its original position.
11. Clean the unit and cover it with a protective cover.
12. Store it in its normal position, in a clean, dry and well ventilated area.
7.1
Diagnostics for minor faults
The unit...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
1172_EN.docx
Check that:
The checks before starting have been performed.
YES
The start-up procedure has been followed
correctly.
YES
The equipment to be used has not been
connected prior to starting.
YES
The spark plug is in good condition and correctly
connected.
YES
The oil level is correct.
YES
The fuel level is correct.
YES
The air filter is in good condition.
YES
Maintenance has been correctly performed on the
unit components.
YES
Have the unit checked by one of our agents*.
The circuit breaker(s) has/have been tripped.
YES
The connected equipment and their power cords
are not faulty.
YES
Have the unit checked by one of our agents*.
Section 6. Transporting and storing the generating set
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
22/28
Section 7. Repairing minor faults
Solutions to be applied:
Perform the necessary checks.
Re-read the start-up procedure and
repeat the start-up attempt.
Disconnect the equipment then try to
start the unit again.
Replace the spark plug (330830005).
Top up with oil.
Fill up with fuel.
Clean the air filter.
Perform maintenance on the unit as
per the recommendations.
Check the capacity of the unit and
press the circuit breakers.
Try with another item of equipment
and another power cord.