2.10
Risks during handling operations, use and maintenance
For safety reasons, all operations must be carried out by staff with the necessary skills and using suitable equipment.
Maintenance must be carried out regularly and properly using only original parts. Personal protective equipment must be
used.
Safety guidelines for handling petroleum products (fuel, oil, coolant):
DANGER
Safety guidelines for handling batteries (if fitted):
DANGER
3.1
Key to illustrations
The cover illustrations can be used to identify the various components of the unit. The procedures in the manual refer to these
illustrations using letters and numbers as identifiers: "A1" refers to the number 1 on figure A.
Earth terminal
Oil dipstick/filler plug
Filler neck
Dipstick upper limit
Dipstick lower limit
Fuel tank cap
Noise deflector
Fuel tap
Air filter
Switch
Choke
The unit may be equipped with the "GS101-Generator Smart Care" option (A16): the Bluetooth GSC101 box
transmits all the information needed to monitor the unit to an application to be installed on your mobile phone; this
includes maintenance dates, a maintenance aid, and the map of approved resellers for any spare parts required.
3.2
Initial commissioning
On taking delivery and commissioning the unit:
1.
Check that it is complete and not damaged in any way.
2.
If the unit is fitted with a transport bracket, remove it.
The transport bracket is a metal plate located underneath the engine, close to the earth terminal.
Although useful for transportation, it will prevent optimum operation of the unit (noise, vibration).
To remove it: lift the unit slightly and place it on a block then remove the nut (1) and the clamp (2).
3.
Check the oil and fuel levels and top them up if necessary.
4.
If necessary, connect the battery, starting with the positive terminal.
Observe the polarity of the battery terminals when connecting it: as this could cause serious damage to the electrical equipment.
Some units require a running-in period. Contact your nearest agent for more information.
1172_EN.docx
The fluids used by the units are dangerous products. Respect the local regulations in force concerning
the handling of petroleum products.
RISK OF POISONING
Never inhale or ingest; avoid prolonged or repeated contact with the skin. Use personal protective
equipment when working on the unit (gloves, shoes, glasses, appropriate clothing). If petroleum
products are exposed to high temperatures for a period of several hours (containers or generating set
stored in a vehicle parked in the sun, for example), harmful vapors could be released causing a risk of
poisoning or discomfort.
RISK OF FIRE OR EXPLOSION
Fill up with fluids when the unit is switched off and the engine cold. Smoking, using a naked flame,
producing sparks and making telephone calls are forbidden when filling with fluids. Always make sure
the cap is properly closed after filling. Clean any traces of fluid with a clean cloth and wait until the
vapors have dispersed before starting the unit.
RISK OF POISONING OR EXPLOSION
Follow the battery manufacturer's recommendations. Only use insulated tools. Keep away from fire or
naked flames. Always ensure adequate ventilation during charging.
A1
Starter-recoil reel handle
A2-B1
Electrical sockets
B2
Oil drain screw
B3
Sediment bowl
B4
Fuel drain screw
A3
Sediment bowl seal
A4
Air filter cover
A5
Nut
A14
Wing nut
A7
Foam element
A6
Paper element
Section 3. Getting started with the generating set
A8
Air filter seal
A9
Exhaust silencer
A10-B5
Spark arrester
A11-C2
Spark arrester mounting bolt
C1
Exhaust silencer protection
C3
Spark plug
D2
Spark plug cap
D1
Circuit breakers
D3
GSC101-Generator Smart Care
D4
D5
18/28
D6
A12
E1
E2
E3
A13-F2
F1
A15
A16
1
2
2023-11-15

Publicité

loading

Ce manuel est également adapté pour:

Intens hx4000 tb uk c5Intens hx6000 tb uk c5