5 | SETTINGS
5.4
Setting continuous operation
6 | MAINTENANCE
Cleaning
Only clean the outside of the pump with a slightly damp cloth and do not use detergents.
CAUTION:
Never clean the display with aggressive fluids, as it can become scratched or opaque.
Replacing the motor head
WARNING:
Depending on the temperature of the fluid and system pressure, when removing the motor head or pump,
hot fluid may be expelled under high pressure.
Close the stop valves and let the pump cool down before removal.
NOTICE:
When the motor is removed while running, noises and a change in rotation may occur. This is normal for this
situation. Faultless function can only be guaranteed when the pump is operated in the fluid.
32
SECONDARY HOT WATER CIRCULATION PUMP EV-ZUP-T 15 PLUS
1.
2.
Select time switching function (flashing)
Select (flashing) to switch off the time
3.
switching function
4.
Select the temperature control (flashing).
Select (flashing) to switch off the
no °C
5.
temperature control
Select "off" (flashing) to switch off the
6.
thermal disinfection
7.
Select the standard display

Publicité