1 | SAFETY
1.5.
Conversion and spare parts
The pump must not be technically modified or converted. Only use original spare parts.
1.6
Transport/storage
Unpack and check the pump and all accessories upon receipt. Report any damage sustained in transit
immediately. Only ship the pump in its original packaging.
Protect the pump from moisture, frost and mechanical damage and do not expose it to temperatures outside
the range of -10 °C to +50 °C.
1.7
Electrical current
There is a danger of electric shock when working with electrical current. For this reason:
• Switch off the power before beginning work on the pump, confirm that the system is voltage-free and
ensure that it cannot be switched on again accidentally.
• Do not kink or pinch the power cable or allow it to come into contact with sources of heat.
• Never open the control module and never remove operating elements.
• The pump is protected against drips in accordance with IP protection class (see rating plate). Protect the
pump from water spray. Do not immerse in water or other fluids.
• Protect the electrical connection with a residual-current device (RCD).
2 | TECHNICAL DATA
2.1
Type key
EV ZUP-T
Series: Standard secondary hot water circulation pump, glandless pump
15 Plus
Type designation
2.2
Connections
EV ZUP-T 15 Plus (Fig. 1)
Screwed connection: DN15 (1/2" IG)
24
SECONDARY HOT WATER CIRCULATION PUMP EV-ZUP-T 15 PLUS