3 | DESCRIPTION AND FUNCTION
3.3
Operation
Operating button
The pump is operated using the operating button.
Menu / Symbols
Clock menu
Settings for current time
Time switching function menu
Settings for parameters:
• Time switching function deactivated, Pump runs in 24-hour
continuous operation
• Time switching function activated
- Setting of 3 possible switch-on times
- Setting of 3 possible switch-off times
Temperature control menu
Settings for parameters:
• Set the temperature
• Thermal disinfection switching on/off
Press > 5 sec: Call up the menu
Press briefly: Menu selection and confirmation of parameter
settings
Turn: Menu selection or parameter settings
SECONDARY HOT WATER CIRCULATION PUMP EV-ZUP-T 15 PLUS
60°C