q
Windbreak.
w
Stainless steel hose clamp.
e
T of 90° with outlet.
t
Insulator.
y
Wooden ground.
u
Non flammable floor protection.
g
Elbow of 90°.
l
*Distance equal to or over 2 metres.
1(
MAXIMUM 1 metre.
Other installations are possible as well (please check with your authorised dealer.) Other possibilities are
added herebelow:
4.27. Outdoor pipe. Take into account the installation of double wall piping.
q
Windbreak.
w
Stainless steel hose clamp.
e
T of 90° with outlet.
t
Insulator.
y
Wooden ground.
u
Non flammable floor protection.
l
*Distance equal to or less than 2 metres.
*
If the tube over 8 m in length, the next larger
size will be used.
4.28. When fitting stoves in brickwork chimneys a perfect seal between the flexible and the rigid pipe must be
achieved. Similarly, the insulation to be placed at the contact areas between the pipe and possibly
inflammable zones must be taken into account. The tube end may be left inside the chimney itself, taking
into account its opening.
Special attention must be paid to the cleaning of the chimney, especially if the latter has been used in a
fireplace or wood stove. If this is the case, we highly recommend thoroughly cleaning the whole conduct in
order to prevent a small fire from starting.
Once installation is complete, we must seal the chimney from the inside of the house.
y u
y u
34
1(
t
q
g
w l
e
Drawing 8
q
l
w
t
e
Drawing 9