10.5 Warnings during normal use
During normal use the User should:
• pay attention to the work area and any dangerous situations
present;
• visually check all the movements of the Machine and the
load;
• stay within the operating range of the Radio Remote Control;
• pay attention to the visual and acoustic signals of the Radio
Remote Control;
• use the Radio Remote Control to move the Machine safely, to
avoid creating dangerous situations for Persons and/or
property;
• switch off the Transmitting Unit and disconnect the power
supply to the Receiving Unit in the event of a malfunction;
• immediately notify superiors and/or managers of the
workplace and/or the Machine of any malfunctions;
• use the Radio Remote Control only after solving and
problems and/or malfunctions;
• use the Radio Remote Control only with a fully charged battery;
• end any dangerous operations as soon as possible in the event
of a low battery.
10.6 Warnings for after its use
Warnings for after its use
• avoid leaving the Machine in dangerous conditions (for
example with a suspended load);
• prevent unauthorised or unsuitable trained persons from
using the Radio Remote Control.
FAILURE TO COMPLY WITH THESE INSTRUCTION SCAN CAUSE
SERIOUS INJURIES OR DEATH AND/OR DAMAGE TO
PROPERTY.
11 Description of the Receiving Unit
A
B
E D
F
G
H
J
C
S
R
M
Q
P
N
M
L
K
A
Rating plate
B
Serial number
C
Cable gland or plug
D
Power supply protection fuse (F1)
e
STOP contacts protection fuse (F2)
F
FEEDBACK input connector
G
Relay STATUS LED
H
START output connector
J
DIP switch
K
STATUS LED
L
START LED
M
Relay
n
Relay connector
P
POWER LED
Q
Address key
R
Receiver radio module
S
Power supply - STOP - SAFETY input connector
T
SAFETY contacts protection fuse (F3)
11.1 Technical data
Radio transceiver module
Antenna
Power supply
Current draw
Absorbed power
Power supply input protection
fuse
STOP contacts protection fuse
SAFETY contacts protection fuse
Maximum rated current of the
control circuit contacts
Maximum capacity of the STOP
circuit contacts
Maximum rated current of the
SAFETY circuit contacts
Maximum contact voltage
Protection degree
Distance between antenna and
human body
Dimensions
T
Weight
The Radio Remote Control was evaluated for RF Exposure of
portable devices.
MRE2
incorporated
⎓
12-30 V
500 mA
<6 W
F1 = 2A MINIBLADE ATM 32V
F2 = 4A MINIBLADE ATM 32V
F3 = 4A MINIBLADE ATM 32V
10 A
4 A
4 A
⎓
30 V
IP65
> 20 cm
110x165x50mm
450 g
187
165
147
13