of the motor which in turn might lead to overheating and damage the motor.
Do not use the pump if the ambient temperature is below zero. Frozen water will damage the device and
the water delivery system to the surface.
Do not obstruct the water outlet when in use.
Use a rope (standard nylon preferably) attached to the pump handle to lift, carry and lower the pump into
a borewell.
The product should be used under the supervision of a person with appropriate knowledge in terms of its
use and operation.
Electrical wiring diagram
Device use
To switch on the pump set the On/Off switch to the On position. If the overcurrent circuit breaker is tripped by
a short circuit, overheating, etc., once the problem has been resolved (the cause of overcurrent circuit breaker
tripping), release the circuit breaker by pressing the circuit breaker button on the control panel housing.
Dismantling the pump
In areas where temperatures drop below zero, dismantle the pump for the winter season and store it in
accordance with the guidelines in "transport and storage" section.
To dismantle the pump:
Set the On/Off switch to the Off ("0") position.
Disconnect the pump from the power source.
Extract the pump from the borewell using steel or a different secure rope attached to the pump handles.
Disconnect the water delivery pipe from the pump.
Empty any water remaining in the pump by turning it upside down.
EN
1- Black
2- Blue
3- Brown
4- Yellow-green