CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The
selected program will be restarted next time the charger is connected.
THE TABLE ExPLAINS THE DIFFERENT CHARGING PROGRAMS:
PROGRAM BATTERY SIzE (AH) ExPLANATION
1.2–14Ah
14–160Ah
14–160Ah
14–160Ah
RECOND
8 • EN
Small battery program
14.4V/0.8A. Use for smaller batteries.
Normal battery program
14.4V/4.3A. Use for WET batteries, Ca/Ca, MF, GEL batteries
and many AGM batteries.
Cold weather program
14.7V/4.3A . Use for charging at low temperatures and for
power AGM batteries like Optima and Odyssey.
Recond program
15.8V/1.5A. Use to return energy to the empty WET and Ca/Ca
batteries. Recond your battery once per year and after deep
discharge to maximise lifetime and capacity. The Recond pro-
gram adds STEP 6 to the normal battery program. Frequent use
of the Recond program may cause water loss in the batteries and
reduce service life of electronics. Contact your vehicle and bat-
tery supplier for advice.
TEMP RANGE
-4ºF–122ºF
(-20°C–+50°C )
41ºF–122ºF
(+5°C–+50°C)
-4ºF–41ºF
(-20°C–+5°C)
-4ºF–122ºF
(-20°C–+50°C )