Battery replacement
Turn the unit off.
Loosen the two captive screws on either end of the battery cover.
Carefully remove battery and disconnect.
Connect new PP3 battery (See section "Specification" for details), place in tester and
replace battery cover.
Note: Only replace with similar size and type of battery.
Replacement of burst discs (No. 573736)
11/16˝ AF
Maintenance and service
Disconnect the unit from the hydraulic
circuit
Locate the new discs - the unit is shipped
with spare discs located in the block
Screw the load valve fully shut - (clockwise)
Unscrew the disc holder from the valve
Remove the disc spacer and ruptured
discs from the valve and disc holder
Carefully shape the two new discs by
pressing them by hand between the disc
holder and spacer
Place the first disc inside the valve
Replace the spacer
Place the second disc on top of the spacer
Screw in the disc holder, tighten to 40 lb.ft
(54 Nm)
Unscrew the load valve fully
Re-connect the unit if required