10.1
Schéma de tuyauterie: unité
intérieure
A
B
d
e
a2
C
p
p
b2
q
r
b1
*s
b3
*t
u
B
d
e
a1
A
Indoor unit
B
Field installed (delivered as accessory)
C
Field supplied
a1
Space heating/cooling – Water IN (screw connection, female, 1 1/4")
a2
Space heating/cooling – Water OUT (screw connection, female, 1 1/4")
b1
DHW – Cold water IN (screw connection, 3/4")
b2
DHW – Hot water OUT (screw connection, 3/4")
b3
Recirculation connection (female, 3/4")
c1
Water IN from outdoor unit (screw connection, female, 1 1/4")
c2
Water OUT to outdoor unit (screw connection, female, 1 1/4")
d
Shut-off valve (male 1" – female 1 1/4")
e
Screw connection, 1"
f
Quick coupling
g
Gas separator
h
Magnetic filter/dirt separator
i
Drain valve
j
Safety valve
k
Air purge
l
Expansion vessel
m
Backup heater
n
Hose for air purge
o
Drain hose for water
p
Shut-off valve (recommended)
q
Non-return valve (recommended)
r
Pressure reducing valve (recommended)
*s
Pressure relief valve (max. 10 bar (=1.0 MPa))(mandatory)
*t
Tundish (mandatory)
u
Expansion vessel (recommended)
B1PW
Space heating water pressure sensor
B2L
Flow sensor
B4L
Gas sensor
M1P
Pump
M1S
3-way valve (space heating/domestic hot water)
M4S
Normally closed shut-off valve (inlet leak stop)(quick coupling – female 1")
EPVX10+14S18+23A
Daikin Altherma 4 H F
4P773386-1 – 2024.11
R1T
n
n
j
o
k
h
g
i
o
B4L
k
R2T
m
B2L
R8T
R5T
R11T
M1S
M
10 Données techniques
B
e
f
M4S
l
B1PW
B
e
d
c2
M1P
Manuel d'installation
B
d
c1
3D151704