Item
Room thermostat
See below table.
(wired or wireless)
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
MMI
▪ [1.12] Commande
▪ [1.13] Thermostat
For the additional zone:
▪ [2.12] Commande
▪ [2.13] Thermostat
Heat pump convector
There are different controllers and
setups possible for the heat pump
convectors.
Depending on the setup, implement a
relay (field supply, see addendum
book for optional equipment).
For more information, see:
▪ Installation manual of the heat
▪ Installation manual of the heat
▪ Addendum
Wires: 0.75 mm²
Maximum running current: 100 mA
This is a ES sur place output
connection. See
ES sur
[13] ES sur place (Mode
MMI
refroidissement/chauffage)
For the main zone:
▪ [1.12] Commande
▪ [1.13] Thermostat
For the additional zone:
▪ [2.12] Commande
▪ [2.13] Thermostat
Remote outdoor
See:
sensor
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
This is a ES sur place input
connection. See
ES sur
[13] ES sur place (Capteur
MMI
extérieur externe)
[5.22] Capteur ambiant
EPVX10+14S18+23A
Daikin Altherma 4 H F
4P773386-1 – 2024.11
Description
d'ambiance
externe
d'ambiance
externe
pump convectors
pump convector options
book
for
optional
equipment
"6.3 Raccordements
place" [ 4 11].
d'ambiance
externe
d'ambiance
externe
outdoor sensor
book
for
optional
equipment
"6.3 Raccordements
place" [ 4 11].
6 Installation électrique
Item
Remote indoor sensor
See:
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
This is a ES sur place input
connection. See
ES sur
[13] ES sur place (Capteur
MMI
intérieur externe)
[1.33] Thermostat externe
décalage
Human Comfort
See:
Interface
▪ Installation and operation manual of
▪ Addendum
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[1.12] Commande
MMI
[1.38] Décalage de capteur int.
Bizone kit
See:
▪ Installation manual of the bizone kit
▪ Addendum
Use the cable delivered with the
bizone kit.
[3.10] Kit bi-zone installé
MMI
For the room thermostat (wired or wireless):
In case of...
Wireless room thermostat ▪ Installation manual of the wireless
room thermostat
▪ Addendum
equipment
Wired room thermostat
▪ Installation manual of the wired room
without multi-zoning base
thermostat
unit
▪ Addendum
equipment
Wired room thermostat
▪ Installation manual of the wired room
with multi-zoning base unit
thermostat (digital or analogue) +
multi-zoning base unit
▪ Addendum
equipment
▪ In this case:
▪ Connect the wired room thermostat
▪ Connect the multi-zoning base unit
▪ For
Description
indoor sensor
book
for
optional
equipment
"6.3 Raccordements
place" [ 4 11].
the Human Comfort Interface
book
for
optional
equipment
book
for
optional
equipment
See...
book
for
optional
book
for
optional
book
for
optional
(digital or analogue) to the multi-
zoning base unit
to the outdoor unit
cooling/heating
operation,
implement a relay (field supply, see
addendum
book
for
optional
equipment)
Manuel d'installation
13