Menu access 4/5
Menu
2nd Menu
Stepper info
6.STAT
Error Logging
3rd menu
Displays status information for all motors and signals
PAN
TILT
PAN OP
TILT OP
Displays the last 8 fault records, faults will not be saved after the lyre
has been reset or switched off.
fault data
12: :03
Hall fault
Hall error
Optocoupler failure
Out of step
Striker
Sensor failure
Fan failure
RACER CMY 350 - EN
Functions
Real-time position value
Real-time position value
Display of the status of the two signal
levels of the Pan axis optocouplers,
binary
Display of the status of the two signal
levels of the tilt axis optocouplers,
binary
total number of failures
Time between power-up and fault.
No valid signal detected
The signal is always valid
No valid signal detected
The motor has missed one or more
steps during operation
Hits the positioning stop when
the motor is reset
Temperature sensor signal error
Main fan operating error