OUTLET FUNCTION
IF THE VOLTAGE SWITCH IS SET TO 120/240V
Set the voltage switch to "120/240"
The output voltage is 120/240V, and the current is only 31.6A without parallel
connection.
2 & 3 120V socket: 120V (Voltage) x 31.6A (Current)=3792W (Output Power)
1 240V: Socket: 240V x 31.6A (Current)=7584W (Output Power)
When two generators are connected in parallel, socket can output 240V
voltage at 50A current:
240V (Voltage) x 50A (Current) = 12000W (Output Power)
attention: The total power output of the socket must not exceed
the rated power of the generator.
Output voltage 120V current 20A
120V (Voltage) X 20A (Current)= 2400W (Output Power)
The output voltage is 120V and the current is 30A.
1 & 2 120V socket: 120V (Voltage) x 30A (Current)=3600W (Output Power)
3 240V: Socket: 240V x 30A (Current)=7200W (Output Power)
attention: sockets 1 2 3 can output at the same time, but the total power output
of the socket can not exceed the rated power, can not be connected to the
same load.
attention: sockets 1
2 3 can output at the
same time, but the total
power output of the
socket can not exceed
the rated power, can
not be connected to
the same load.
13