Télécharger Imprimer la page

Porter Cable CPF6020 Manuel D'instructions page 17

Publicité

To Replace Regulator
1.
Release all air pressure from air tank. See
"To Drain Tank" in the Maintenance
section.
2.
Unplug outfit.
3.
Using an adjustable wrench remove the
outlet pressure gauge and quick connect
from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the nipple on
the standpipe.
6.
Assemble the regulator and orient as
shown.
NOTE: Arrow indicates flow of air. Make sure it is
pointing in the direction of air flow.
7.
Reapply pipe sealant to outlet pressure gauge
and quick connect.
8.
Reassemble outlet pressure gauge and quick connect. Orient outlet
pressure gauge to read correctly. Tighten connect with wrench.
D26348
All manuals and user guides at all-guides.com
Regulator
Regulator
Regulator
18- ENG
Outlet
Pressure
Gauge
Quick
Connect
Nipple
Arrow

Publicité