INSTALLATION and Start-Up MANUAL FOR TEKNA SERIES DOSING PUMP
Your pump is part of the pump family listed in the following table:
INTRODUCTION
The dosing pump is comprised of a control unit that houses the electronics and the magnet, and a hydraulic part in
contact with the liquid to be dosed.
145
5
4
6
7
The parts in contact with the liquid have been chosen in order to guarantee perfect compatibility with most chemical
products normally in use. Given the range of chemical products available on the market, we recommend checking
the chemical compatibility of the dosed product and contact materials.
MATERIALS USED IN THE PUMP HEAD (STANDARD)
BODY:
CONNECTORS:
DIAPHRAGM:
BALL VALVES:
The pumps are supplied complete with the indispensable accessories for their correct installation. You will find the
following in the packaging:
Foot filter, injection valve, transparent suction tube, transparent tube for bleed valve, opaque delivery tube, Pump
fixing inserts, bracket for wall mounting, level sensor connector and instruction manuals.
READ THE FOLLOWING PRECAUTIONS CAREFULLY BEFORE PROCEEDING WITH PUMP
CAUTION! PRODUCT INTENDED FOR PROFESSIONAL USE, BY SKILLED PEOPLE
CAUTION! ALWAYS DISCONNECT THE POWER SUPPLY BEFORE INSTALLING OR CARRYING OUT
CAUTION! FOLLOW THE SAFETY PROCEDURES RELATIVE TO THE DOSED PRODUCT
H
SO
SULPHURIC ACID
-
2
4
react with water, dry all the internal parts of the plumbing thoroughly.
-
Install the pump in a zone where the environment temperature does not exceed 40ºC and the relative humidity
is below 90%. The pump has an IP65 protection level.
-
Install the pump so that any inspection and maintenance operations are easy to carry out, then secure the
pump firmly in order to prevent excessive vibrations.
EM00136168
MODEL 1 OR 6 l/day
Flow Rate
Flow Rate
l/h
0,250
0,041
2
3
1
PVDF
PVDF
PTFE
CERAMIC
PRECAUTIONS
INSTALLATION OR MAINTENANCE
MAINTENANCE ON THE PRODUCT
All the pumps are tested with water. When dosing chemical products that may
Connections
(mm)
l/day
Int / Ext
6
4/6
1
119
rev. 1.1
1 Power switch
2 Regulation area
3 Dosing head
4 Priming valve
5 Delivery connector
6 Suction connector
7 Base support (optional)
1