To use the dehumidification function, connect the water drainage hose to the
water drainage point (9). This hose should lead to a bucket or drain. The hose
should not run upwards! Your unit is now ready for use.
In order to use the cooling function, you do not need to connect the water
drainage hose. Check that the sealing plugs of the water outlet connections are
installed.
Place window panel in the window opening, see diagram. The length of the window
panel can be adjusted from 67.5 to 123 cm.
Screw on the connector for the air conditioner on one end and the connector for
window panel on the other end of the outlet hose.
Slide the connector for the air conditioner into the appropriate slot on the rear of
the unit.
Secure the other end of the outlet hose in the window panel opening so that it can
remove hot air outside.
You can also hang the outlet hose out of an open window; this method is less
efficient however.
Avoid bends or pinches in the pipe. These will lead to a build-up of damp, waste air
which can cause leaks, overheating or lead to the air conditioning unit switching
off.
Warning! Do not use your air conditioner before it is installed according to the
instructions described above!
Warning! Ensure that no water can enter the device!
Warning! The length of the drain pipe is specially adapted to the technology of
this air conditioning. Do not replace it, therefore, and do not extend it with its own
hose, as this can negatively affect the functioning of the air conditioner. The hose
can be stretched, but in order to achieve an optimal effect you should keep the
length as short as possible.