System Message
Update error
High temp on ch #
Channel attenuated
Over temp on ch #
Channel muted
Concernant les messages liés à la température :
cause possible
température ambiante trop basse / trop élevée
ltre bouché
contrôleur amplié mal ventilé
ressources des canaux sollicitées à leurs limites
impédance de l'enceinte trop basse
61
Displayed if the rmware update has failed. Try to restart the amplied controller. If
the issue persists, check that each L-NET cable is in working order and is correctly
plugged on both ends and relaunch the update process. If the issue persists, contact
L-Acoustics.
Displayed if temperature at an output channel is above 85° C. The signal delivered
at the output channel is attenuated until temperature returns to nominal conditions.
Displayed if temperature at an output channel is above 96° C. The signal delivered
at this output channel is muted until the temperature returns to nominal conditions.
diagnostic / procédure
s'assurer que la température ambiante est dans la plage
de fonctionnement du contrôleur amplié (0º C / 32º F à
+50º C / 122º F)
nettoyer le ltre
installer le contrôleur amplié de manière à ne pas
bloquer les panneaux avant et arrière (pas d'objets ou de
structures).
Lorsque le contrôleur amplié est monté dans un rack :
— ne pas bloquer les grilles de ventilation avant et
arrière (pas de portes ou de panneaux), ou utiliser
une ventilation forcée
— lorsque plus d'un contrôleur amplié est utilisé, les
xer directement les uns au dessus des autres, ou
fermer les espaces libres à l'aide de panneaux
surveiller les indicateurs LED : en cas de niveau élevé ou
de saturation persistante, réduire le niveau de sortie de
la source sonore (consulter la documentation tierce) ou la
valeur de gain du canal.
vérier que rien ne cause de court-circuit à la sortie
(schéma de câblage incorrect, câble endommagé ou court-
circuit dans le haut-parleur).
Maintenance