BEFORE USING CHECK THAT THERE ARE NO LEAKS.Check the leakage of your device only outside. Do
not seek the leakage with a match but use water and soap or a gas detector (our article Revelgas cod. 1726).
Apply solution of soap and water or gas detector in the interspaces of the unit. If bubbles appear, it means that
there is a leak and it must be repaired before use. If you detect a leak and you cannot repair it, don't try to fix it
another way, but contact the customer service. Do not use a device that leakage, deteriorated or malfunctioning.
Starting the appliance
Don't use the hot plate other purposes than cooking.
1.
2.
Put the hot plate on a stable and horizontal surface. Do not alongside two or more burners.
3.
Put the hot plate far from inflammables substances or things that can be damaged by heat.
4.
Make sure that in the hot plate, the lever connecting the cartridge is in "UNLOCK" position and the gas valve
knob is in "OFF" position.
5.
Make sure that the seals are in a good state before connecting the gas
cartridge.
6.
Never use the appliance with damaged or worn seals.
7.
Never use the appliance if it leaks, is deteriorated or malfunctioning.
8.
Put the cartridge in its slot, placing the cut on its neck in correspondence
to the safety stop.
9.
Place the lever connecting the cartridge on the "LOCK" position.
WARNING: the appliance is now ready for use. The positioning of the lever
on "LOCK" presupposes the immediate ignition of the stove as the gas
circuit is ready for gas supply. Do not leave the appliance unattended and
without flame with the lever positioned on "LOCK".
WARNING: the openings at the base of the burner provide air for
combustion, they should never be obstructed.
WARNING: Closed the cartridge cover before lighting. Not closing the
cover can cause the cartridge to overheat.
10. Push and turn anticlockwise all the way the cock until it is positioned on
"ON" where the piezo ignition will ignite the flame.
11. If the stove dose not light, turn the control knob back to "OFF" position and repeat.
12. If after three failed attempts, the stove dose not light, turn the control knob to the "OFF position and move
the cartridge lever to the "UNLOCK" position.
13. Open the cartridge cover and remove the cartridge, Shake the cartridge to see if it is empty. If empty, replace
the cartridge and repeat from point 9.
14. Regulate the flame according to your needs.
15. Warning: the device is not equipped with a safety system for the automatic closing gas (thermocouple).
Shutting down the appliance
1.
To turn off the appliance, rotate clockwise the cock to the "OFF" position and wait until the flame is fully
extinguished before performing the next step.
2.
Position the cartridge-connecting lever on the "UNLOCK" position and remove the gas cartridge from the
compartment.
3.
Wait for the plate to cool before storing it.
4.
In case of long periods of no use of the product, it is compulsory to take the cartridge out of the appliance.
5.
This unit can be kept inside only if the cartridge has been disconnected and removed from the appliance. If
you expect that the barbeque remains unused for a certain period of time, store it in its original packaging
and in an environment free from dust.
THE AUTOMATIC SAFETY SHUT-OFF DEVICE ACTIVATION
When used in high temperature areas, (such as the beach during
summer or in a hot environment) or in places where there is a risk of
overheating the cartridge, the internal pressure of the cartridge may rise.
This will activate the Automatic safety shut-off device inside the regulator.
1.
Remove the gas cartridge from the compartment and let it cool down.
2.
Press the red safety lever of the valve to reset the appliance and at
the same time turn the ignition knob to "ON" to any excess gas inside
the regulator.
3.
After having cooled down the cartridge and emptied the gas circuit,
proceed with normal ignition.
IMPORTANT WARNING: IF YOU CAN NOT FIND THE CAUSE OF THE SAFETY
THE PREVIOUS PROBLEM IS REPEATED, CONTACT THE CUSTOMER SERVICE.