3 Installation
3.1 Internal wire diagram
Brown
L
Blue
N
Yellow/Green
E
3.2 Installation instruction
1. This electrical water heater shall be installed
on a solid wall. If the strength of the wall can-
not bear the load equal to two times of the to-
tal weight of the heater filled fully with water, it
is then necessary to install a special support.
Incase of hollow bricks wall, ensure to fill it with
cement concrete completely.
2. After selecting a proper location, determine the
positons of the two install holes used for expan-
sion bolts with hook (200mm), Make two holes
in the wall with the corresponding depth by us-
ing a chopping bit with the size matching the ex-
pansion bolts attached with the machine, insert
the screws, make the hook upwards, tighten the
nuts to fix firmly, and then hang the electrical
water heater on it (see Fig.2).
Expansion bolt (with hook)
10 / EN
Thermal
Thermostat
Cut Out
Q
Power
Indicator
(Fig.2)
Q
3. Install the supply socket in the wall. The require-
ments for the socket are as follows: 250V/10A,
single phase, three electrodes. It is recommend-
ed to placed the socket on the right above the
heater. The height of the socket to the ground
shall not be less than 1.8m (see Fig.3).
L (Brown)
E (Yellow/Green)
N (Blue)
4. If the bathroom is too small, the heater can be
installed at another place. However, in order
to minimize the heat loss caused by the long
pipeline, the water heater is suggested to be
installed as close as possible to the outlet point.
3.3 Pipelines connection
1. The dimension of each pipe part is G1/2" ; The
massive pressure of inlet should use Pa as the
unit; The minimum pressure of inlet should use
Pa as the unit.
Electric Storage Water Heater / User Manual
≥1.8m
Ground
(Fig.3)