10. Troubleshooting guide
Faults
The equipment
does not start.
The equipment
does not pump.
Insuffi cient pumping
rate.
The equipment
switches off after
briefl y running.
Anl_GE_DP_18_25_LL_Li_SPK7_NA.indb 14
Anl_GE_DP_18_25_LL_Li_SPK7_NA.indb 14
EN
Cause
- Battery is not correctly inserted.
- Intake sieve clogged.
- Discharge hose kinked.
- Intake sieve clogged.
- Performance reduced due to
heavily contaminated and abrasive
water impurities.
- Battery performance decreasing.
- Motor circuit-breaker switches the
equipment off due to excessive
water contamination.
- Water temperature too high;
motor circuit-breaker switches the
equipment off .
- 14 -
Remedy
- Remove battery and insert again.
- Clean intake sieve with water jet.
- Unkink the hose.
- Clean intake sieve.
- Clean equipment and replace wear
parts.
- Check the battery performance and
charge the battery if necessary.
- Take out the battery and clean the
equipment and the shaft.
- Ensure that maximum permissible
water temperature 95°F (35°C) is
not exceeded.
14.06.2024 10:25:11