GALEOBT, GALEOBT BLACK
Backlit Bluetooth keypad and remote electronics
1] PRODUCT PRESENTATION
GALEOBT is an innovative surface mount keypad combining sleek and stylish aesthetics
with robust security. With a remote electronic controller and vandal-resistant body, this
keypad minimises the risk of the system being disabled through tampering. GALEOBT
is Bluetooth-enabled, and its free iOS or Android app makes programming easier than
ever. With a simple and intuitive interface, you can quickly set up all the key parameters
directly from your smartphone.
3 relay outputs
Backlit keys
100 user codes
Finish: Zamak®
Technology: Bluetooth
Free voltage
Operating voltage:
- 12V to 24V AC
- 12V to 48V DC
Consumption: With the 3 relays
activated and keypad lit
12 V
24 V
48 V
AC
166 mA
82 mA
-
DC
195 mA
105 mA
54 mA
2] PACKAGE CONTENTS
GALEO
®
(M4x10)
T20
Mounting
Screw
plate
Varistor
Torx®
Torx®
cap
(keypad)
screw
spanner
1
1
1
1
1
3] SPECIFICATIONS
Feature
Description
Indoor/outdoor use (IP64) Keypad and keys polished in heavy duty Zamak
resistance to vandalism
Intuitive programming
100 user codes customisable by each user
Feedback
Audible and visual feedback
Default programming
There is no master code in the factory setting (5 digits)
Two programming options
Use the TMGALEO keypad or the app to programme the remote
electronics
2
IP64
WEEE & RoHS
CE Certification
-25°C to 70°C
IK10
UKCA Certification
(x4)
Mounting
Sealed
Sealed
plate
cap
cap
(remote
Ø20mm
Ø25mm
electronics)
2
2
1
with high
®
EN
EN
Backlit Bluetooth keypad and remote electronics
4] WIRING AND CONNECTIONS
The memory can be reset
with the P1 jumper. Switch
off the power. Place the
jumper on P1 and switch
the power back on to reset
the memory.
P2 jumper allows to the user to
modify its own PIN code.
To enable this feature put the
jumper on.
Recommended power supplies
ADC335
Terminal
V
INPUT
V
NC
DOOR 1
C
NO
NC
DOOR 2
C
NO
NC
DOOR 3
C
NO
PB1
Push
M
button
PB2
PX
Clock
H
H
+
Keypad
-
TMGALEO
E
GALEOBT, GALEOBT BLACK
BP1
BP2
PB1
PB2
ADC612S
Wiring table
Input voltage 12V to 24VAC or 12V to 48VDC
Input voltage 12V to 24VAC or 12V to 48VDC
N/C contact relay 1
Common relay 1
Request-to-exit inputs
N/O contact relay 1
PB1 request-to-exit input activates
relay 1.
N/C contact relay 2
PB2 Request-to-exit input activates
Common relay 2
relay 2.
N/O contact relay 2
N/C contact relay 3
Mode and programming time are
programmable.
Common relay 3
N/O contact relay 3
The H input can be used with a time
Request-to-exit input relay 1
switch to allow free access after any
Common of inputs
button on the code.
Request-to-exit input relay 2
When the contact between the right
Not used
Not used
'H' and 'M' is open, the request for
Not used
Not used
access is disabled. When the contact is
Timer Contact
closed, you can press any key to open
relay 1.
White wire from keypad
Brown wire from keypad
Green wire from keypad
P2
P1
3

Publicité

loading

Ce manuel est également adapté pour:

Galeobt blackGaleo black