Wagan Tech Power Dome LT Guide D'utilisation page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

User's Manual—Please read before using this equipment.
Troubleshooting
Problem
Lack of power output
LED light fails to activate
Television/Power Tool will
not start
Television picture breaking
up (snow).
Wagan and wagan.com are trademarks used by Wagan Corporation.
Possible Causes
Power center voltage below
12 volt.
Excessive current drawn by
appliance being operated
Inverter not adequately
warmed up.
Inverter fuse blown.
Inadequate power or exces-
sive voltage drop.
Inverter is overloaded.
High surge wattage require-
ment to start-up.
Television Interference
© 2008 Wagan Corporation.
All Rights Reserved.
Remedy
Recharge the Power Center
immediately.
Reduce load to maximum
200 watts.
Turn off the device and
inverter. Disconnect the
device. Turn the inverter on
for a minimum of 2 minutes.
Turn off inverter, quickly
plug in the device to the
inverter, making sure the
device is off prior to con-
nection. Turn on the inverter
and the device.
Replace a new 25 AMP
rated fuse. To replace fuse:
remove fuse with needle
nose pliers and replace with
a new 25 AMP fuse.
Check Power Dome LT,
recharge if voltage drops
below 12 Volts
Replace load to a max of
200 watts.
Toggle the Master On/Off
switch in quick succession
5 times in order to generate
the necessary power to start
the device. If the device
does not start up in 5 cycles
of ON/OFF trials, this
inverter will not work with
the device.
Move the Power Dome LT
as far as possible from TV,
the antenna and the coaxial
cable.
TV station may be out or
range.