Range ........................... Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature]
Sensing Angle .............. Up to 110°
Electrical Load.............. Up to 200 Watt Maximum Incandescent [Up to 100 Watt maximum each lamp holder]
Power Requirements .... 120 VAC, 60 Hz
Operating Modes .......... TEST, AUTO and MANUAL MODE
Lamp Modes................. Security, BulbSaver, AlertFlash
Time Delay ................... 1, 5, 20 minutes
D
B
Timer .......... Off, 3, 6 hours, Dusk-to-Dawn
®
ual
rite
Replacement lamp........ T4 100W, G8 halogen bi-pin 120 VAC
SYMPTOM
POSSIBLE CAUSE
Light will not come on.
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Sensor does not detect objects in desired area.
Light comes on in day-
1. Light control may be installed in a relatively dark
light.
location.
2. Light control is in TEST.
Light comes on for no
1. Light control may be sensing small animals or auto-
apparent reason.
mobile traffic.
2. Range is set too high.
3. D
ual
Light turns off too late in
Light control may be installed in a relatively dark location. Relocate light control, or use 3 hr. or 6 hr. setting.
Dusk-to-Dawn setting.
Light stays on continu-
1. A lamp is positioned too close to the light control or
ously.
pointed at nearby objects that cause heat to trigger
the light control.
2. The light control may be picking up a heat source
like an air vent, dryer vent, or brightly painted, heat-
reflective surface.
3. Light control is in manual mode.
Light flashes on and off. 1. Heat or light from the lamps may be turning the light
control on and off.
2. Heat being reflected from other objects may be turn-
ing the light control on and off.
3. Light control is in the TEST mode and warming up.
4. Light control is in AlertFlash mode.
Light flashes once, then
Light control is detecting its own light.
stays off in manual
mode.
203017-02
All manuals and user guides at all-guides.com
SPECIFICATIONS
TROUBLESHOOTING GUIDE
B
®
timer is on.
rite
SOLUTION
1. Turn light switch on.
2. Check lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim sensor to cover desired area. Increase sen-
sitivity.
1. Relocate light fixture to another junction box with
increased amount of daylight.
2. Set control switch to 1, 5, or 20 minutes.
1. Re-aim light control.
2. Reduce range. Turn Range Boost off.
3. Turn D
B
ual
rite
1. Reposition the lamp away from the light control or
nearby objects.
2. Reduce range. Re-aim sensor.Turn Range Boost off.
3. Switch light control to AUTO.
1. Reposition the lamps away from the light control.
2. Reposition light control.
3. Flashing is normal under these conditions.
4. Flashing is normal in this mode. Select Security or
BulbSaver mode to turn flash mode off.
Reposition lamps to keep area below the light control
relatively dark.
5
®
Timer off.