Storage
It would help if you permanently stored the generator in a clean, dry and frost-free place.
If the power generator is to be stored for an extended period, please proceed as follows:
Shut off fuel cock and unscrew oil filter cup counterclockwise, drain and blow out
clean.
Position suitable drain container under the drain, open fuel tap and drain fuel entirely
into the container.
Replace a sealing ring (rubber) and screw the oil filter cup back in clockwise.
Loosen carburettor drain plug and drain residual fuel from the carburettor into a
suitable container. Tighten the carburettor drain plug again.
Unscrew the oil filler cap, unscrew the oil drain plug and completely drain oil from the
crankcase into a suitable container.
Tighten the oil drain plug again and fill it up with suitable engine oil up to the upper
mark on the dipstick.
Screw the oil filler cap back into the oil filler neck.
Pull the starter rope in a controlled manner until resistance is felt.