least 3m from any flammable wall or ceiling and must never be directed towards the gas
bottle.
1.16. Only use original gas hose and spare parts.
1.17. Heaters described in this leaflet are not intended for domestic use.
1.18. In the case that a gas leak is found or suspected, immediately close the gas cylinder,
switch the heater off and do not use it again until it has been checked by a qualified
service centre. If the heater is installed indoors, provide a good ventilation by opening
door and windows completely. Do not produce sparks or free flames.
1.19. If in any doubt contact your supplier.
1.20. Use a cylinder of maximum 50 kg.
2. INSTALLATION
2.1 Connect the heater to a suitable electrical outlet 100-240V~, 50-60Hz power source or
use the DC20V battery
2.2 Make sure that the machine is properly earthed.
2.3 Connect the gas supply hose to the pressure regulator and connect the regulator to a
suitable PROPANE cylinder.
2.4 Open the tap of the cylinder and check the supply hose and fittings for gas leak. For this
operation it is recommended to use an approved leak detector.
2.5 NEVER USE NAKED FLAMES.
2.6 For automatic appliances, connect the room thermostat to the socket on the appliance
and adjust it to the required temperature.
3. INSTRUCTION FOR USE
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage.
2. Connect the hose and regulator assembly to the PROPANE cylinder by rotating the nut
counterclockwise into the PROPANE cylinder's valve outlet and securely tighten.
3. Open the cylinder's gas valve and check all gas connections with a soap and water
solution.
4. Connect the power cord to a well-grounded 100-240V~, 50-60Hz power source or use the
DC20V battery (Fig 2) (Fig 3)
(Fig 2.)