Compressed Air Connections - Festo Quickstepper FSS-12-C Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
Quickstepper
Fitting pneumatic components

6.4 Compressed air connections

Connect the inputs and outputs of the Quickstepper with the elements of your
controller according to the circuit diagram.
6.5 Sequence programs with less than 12 steps
You can use a plug set FSS−KM−8−12 (chapter 11) to short−circuit any unneeded
outputs and inputs by pressurising . The bridge connects inputs X
each other. The corresponding outputs A
1. Return the Quickstepper to home position by resetting (step 12).
2. Shorten the plug set (Fig. 12) to the
number of steps required by the Quick
stepper.
3. Plug the plug set on the plug nipple not
required for the inputs X
A
of the Quickstepper.
n
4. Connect the compressed air connection P
to the lowest input X to be bridged via the
hose connector 1.
5. Close the plug set with the plug 2.
The consecutive can be alternatively pressur
ised using barbed hose connectors V−PK−3
(Fig. 14) and PU hoses PU−3−... (chapter 11).
The unused outputs can then be sealed with
the caps CV−PK−3−B (Fig. 13).
The short−circuiting method by means of pressurising allows you to switch 15 %
faster than short−circuiting by means of looping.
Please note
Prolonged flow of compressed air when short−circuiting by means of pressuris
ing can reduce the service life of the product.
Festo FSS−12−C 0410a English
are sealed with blind plugs.
n
and outputs
n+1
n+1
2
Fig. 12
Fig. 13
lying next to
1
P
X
27

Publicité

Table des Matières
loading

Table des Matières