Télécharger Imprimer la page

Stagnoli ACNSEM3L Manuel D'instructions page 23

Masquer les pouces Voir aussi pour ACNSEM3L:

Publicité

DESCRIPTION OF THE PRODUCT
The control board is used to control two or three-light traffic lights in parking areas, residences and in all those
areas where it is necessary to control access.
The control unit has an electrical and mechanical inter block, to prevent in the case of malfunction coming on
contemporaneously of the two green lights.
The control unit can be used with 24V or 230V lights.
The control unit comes with 3 different codes:
-
basic version (power 24V ac/DC alternating or direct current)
-
version with transformer (power 230Vac)
-
version with batteries in buffer (power 230Vac)
ELECTRICAL CONNECTIONS
1) + 24Vac/DC power .
2) - 24Vac/DC power .
3) R2. output relay (clean contact 5A max) red light traffic light 2.
4) A2. output relay (clean contact 5A max) yellow light traffic light 2.
5) V2 output relay (clean contact 5A max) green light traffic light 2.
6) Traffic lights common relay.
7) R1. output relay (clean contact 5A max) red light traffic light1.
8) A1. output relay (clean contact 5A max) yellow light traffic light 1.
9) V1. output relay (clean contact 5A max) green light traffic light 1.
10) Traffic lights common relay.
11) Control common (+24VDC )
12) IN1 ( Input1 ), input for detection devices (N.O or N.C) traffic light 1
13) IN2 ( Input2 ), input for detection devices (N.O or N.C) traffic light 2
14) IN3 ( input 3 ), emergency input N.C or N.O.
15) Auxiliary voltage output +24V, 400mA max
16) Auxiliary voltage output -24V, 400mA max
DEFINING THE COMPONENTS OF THE CONTROL UNIT
F1- fuse to protect auxiliary output 24V
F2- fuse to protect traffic light output.
LED1 – Three-colour led showing status (red/yellow/green light) of traffic light 1.
LED2 – Three-colour led showing status (red/yellow/green light) of traffic light 2.
DISPLAY- 4 digit display for setting operations
IN3 – Activating input 3 (EMERGENCY) in the case of traffic lights with two lights, this means the start of a flashing
sequence of the red traffic lights until deactivation of input3.
TECHNICAL DATA
Power card: 24V ac/DC (+- 10%).
Current consumption at rest: 0.02 A (at 24VDC).
Maximum current switching relay 5A.
Maximum current accessories : 0.4A at 24Vac/DC.
Power to panel with transformer: 230V ac (+- 10%) 50Hz.
Current consumption at rest: 0.04 A (at 230Vac).
Power to panel with transformer and batteries: 230V ac (+- 10%) 50Hz.
Current consumption at rest: 0.04 A (at 230Vac).
Capacity of batteries in buffer: 3Ah
Time required to completely charge batteries in buffer: 24h