Quick Start Guide
English
General features
Power supply
Optional additional outputs: 2 x 0/4-20 mA or 2 x 0-5/10 V (additional consumption for 24 V model:
Outputs
Galvanic isolation
Consumption with probe
and without option
Electrical connections
Relays (optional)
Communication RS485
Digital: Modbus RTU protocol, configurable communication speed from 2400 to 115200 Bauds
(option)
Ethernet communication module allowing transmission, monitoring and maintenance of transmitters via
Communication Ethernet
an Ethernet network in 10 BASE-T and 100 BASE-TX LAN/WAN supporting TCP/IP protocol
(option)
Audible alarm
Environment and type of
fluid
Conditions of use
(°C/%RH/m)
Storage temperature
Security
European directives
*2 additional outputs (optional)
C 310
Multifunction transmitter
2 inputs for
Up to 4 analogue
interchangeable
outputs (4 wires) 0/5-
probes plus internal
0-5 / 10 V
4-20 mA
10 V or 0/4-20 mA
pressure sensor
4 visual (dual-color
Modbus interface
LEDs) and audible
(via RS485 or
alarms
Ethernet connection)
24 Vac / Vdc ±10% or
100-240 Vac, 50-60 Hz
Warning: risk of electric shock
2 x 0/4-20 mA or 2 x 0-5/10 V (4 wires)
1 VA / for 110-240 V model: 2 VA)
Common mode voltage <30 VAC / Maximum load: 500 Ohms (0/4-20 mA)
Minimum load: 1 K Ohms (0-5/10 V)
Inputs (power supply) and outputs (on 110 Vac/240 Vac models)
Device fully protected by
DOUBLE ISOLATION or REINFORCED ISOLATION
Outputs (on 24 Vac/Vdc models)
C310-BO and C310-BN: 6 VA
C310-HO and C310-HN: 8 VA
(CO
probe additional consumption for 24 V and 110-240 V models: 2 VA)
2
Screw terminal block for cables from 0.05 to 2.5 mm2 or from 30 to 14 AWG
Carried out according to the code of good practice
4 RCR relays. NO: 5A / NC: 3A / 240 Vac
(additional consumption for 24 V model: 5 VA / for 110-240 V model: 8 VA)
(additional consumption for 24 V and 110-240 V models: 1 VA)
Buzzer (70 dB at 10 cm)
Air and neutral gases
From -10 to +50°C. In non-condensing condition.
From 0 to 2000 m
From -10 to +70°C
Protection class 2; Pollution degree 2; Overvoltage category 2
2014/30/EU EMC; 2014/35/EU Low Voltage;
2011/65/EU RoHS II; 2012/19/EU WEEE
Features of the housing
Material
Protection
°C
°F
Display
Cable gland
Weight
Symbols used
For your safety and in order to avoid any damage of the device, please follow the procedure described in
this document and read carefully the notes preceded by the following symbol:
The following symbol will also be used in this document, please read carefully the information notes
indicated after this symbol:
Connections
Analogue output 1
(OUT 1)
For 24 Vdc/Vac power supply models:
1.
SPI-2 board (optional)
2.
Solenoid valve
3.
LCC-S software connection
4.
Autozero
5.
Ethernet board (optional)
6.
Relays board (b) (optional)
7.
RS 485 connection (d) (optional)
ABS V0 as per UL94
IP65
Graphic from 1 to 4 lines, 240 x 128 px;
Size: 86 x 51 mm, Backlit
Height of digits:
Values: 10 mm; Units: 5 mm
In polyamide for cables Ø9 mm maximum
700 g
All dimensions are in millimeters.
1
6
3
2
4
9
7
5
8
10
12
13
11
(a)
Optional
Relay 1
Analogue output 2
Analogue output 3
Analogue output 4
(OUT 2)
(OUT 3)
(OUT 4)
(c)
For 115 Vac or 240 Vac power supply models:
or
8.
9.
10.
11.
12.
13.
158
81
(b)
Relay 2
Relay 3
Relay 4
(d)
Modbus
1 2 3
Analogue outputs (a) (OUT3 and OUT4 are
optional)
Power supply terminal block (c)
Type of power supply of the transmitter
Pressure connection (optional)
Probes connection
Cable glands