3.
Before installation
3.1.
Check that all the parts and tools needed for the installation are available.
3.2.
Make sure that the heating load is equivalent to the thermostat power rating.
3.3.
Measure the insulation resistance and the circuit resistance of the heating load con-
trolled by the thermostat. For more information, please see the heating load instructions.
4.
Installation
4.1.
When the thermostat is used for underfloor heating solutions, put the sensor cable in
a dry protective tube between heating cables. NOTE! Make sure that there is not water in the
protective tube.
4.2.
Connect the earthing wires (PE) to the separate connector.
4.3.
Install the thermostat in the mounting box with a screw on each side.
4.4.
Make sure that the power button in the cover is in down position and also the switch pin
on the thermostat is in down position (1).
4.5.
Install the frame and carefully press the cover with display onto the thermostat. Put the
upper part (2) first and then press the lower part (3) to its place.
4.6.
Confirm the placement by carefully pushing the cover onto the thermostat (4).
4.7.
Start the thermostat by switching the power button on the thermostat to up position (5).
Note! Do not apply pressure to the corners of the display cover or to the display itself.
1
5.
Uninstallation
5.1.
Make sure the power switch is in down position, power off (6).
5.2.
Press the cover latch carefully with screwdriver to open the cover plate from bottom (7)
and remove the cover (8). Note! Do not open the four latches on the backside of the thermostat
(9).
5.3.
Uninstall the frame.
5.4.
Open the 2 screws from the mounting box.
6
2
3
8
7
RAK110 / 2024-08-27
4
4
5
9
N
L
L
N
ECO16TOUCH
16A / 230 VAC, 50Hz, IP21
Underfloor heating thermostat
Legrand Finland Oy
Linnoitustie 11
02600 Espoo, Finland
Sensor
T25