STARTING THE AIR CONDITIONER cont.
1. Please put batteries into the remote control.
2. r P ess POWER once to turn on the air conditioner.
NOTE:
W
h
e
n
the air conditioner is first plugged in, the LED display will show "88" for 3 seconds.
After the air conditioner is turned on for the first time, the display will show the
temperature 72 °F and the fan is automatically set to Quiet speed and the Mode indicator
will show ENERGY SAVE.
NOTE: T o switch the temperature display between Fahrenheit (°F) and Celsius(°C), the air
conditioner must be plugged in and turned on. On the control panel on the front of the AC,
press the UP and DOWN button at the same time and hold for 3 seconds. Press F/C button
on remote control to switch between Fahrenheit (°F) and Celsius (°C).
NOTE: Each time this ENERGY STAR Qualified air conditioner is turned on, it will operate in energy
save mode per the EPA requirements. You can select any other mode to satisfy your
needs.
3. Select Mode. Refer to "Mode."
4. Select Speed. Refer to "Speed."
5. Set Timer. Refer to "Temp/Time"
6. Reset the filter. Refer to "Filter Reset"
MODE
1. Press MODE until you see the indicator light come on next to the desired setting.
2. Choose Fan, Cool, Energy Save, or Dehum.
FAN― Only the fan runs. Press SPEED to select High, Med or Quiet fan speed. The display shows
the current room temperature.
NOTE: n I fan mode, the temperature cannot be set.
ENERGY SAVE― In this mode the fan runs only when cooling is needed. The fan will run for 3
minute after the compressor shuts off. The fan then cycles on for 2 minutes
at 10 minute intervals until the temperature in the room is above the set
temperature. The compressor then turns back on.
COOL― Cools the room. Press SPEED to select High, Med, Quiet or Auto Cool fan speed. Press
the TEMP/TIME
continuously in cool mode.
DEHUM―
i A
s d
in removing humidity from the room. Dehum mode cannot be used to cool room.
NOTE: In Dehum mode, when the set temperature is close to ambient temperature, the
compressor may stop and the fan will run in Quiet speed only.
or
arrow button to adjust the temperature. The fan will run
USING YOUR AIR CONDITIONER
PAGE 15

Publicité

loading

Ce manuel est également adapté pour:

Esaq406tHwq08xct