Reset All Data
 DMX connection and DMX protocol
The device is controlled by universal DMX 512 protocol, DMX address is the start channel used
to receive instructions from the external controller. For independent control, each fixture must be
assigned its unique address control channels. For example, this device has four channel modes:
17/21, if we set the mode at standard 17 channels mode, and there are several models need to
be independently controlled, we just simply address first fixture at 1, and second fixture at 18,
third one at 35, etc.
If the devices have the same address, they will behave synchronically.
DMX addressing is limited, don't set the address so high that without enough control channels
for the fixtures.
Display is flashing when no DMX signal is received.
Connection: use DMX cable with 3+5 pin XLR-plugs to connect the controller with the fixture or one
fixture with another.
LUMINA H200 User's Manual Ver. 1.00
:
Gobo 8
:
Max Temperature
Yes/No(No)
:
FOCUS
80~139°C/176~282°C
12