When Indoor Evaporator Unit is powered from the Outdoor Condenser Unit
Evaporator Unit (Indoor)
Indoor
Diagram 1
12
Electrical Connection
INPUT POWER:
11
100-240V,
50/60Hz, 2.5A (MAX)
12
ALARM RELAY:
125V 6.3A max
or
250V 2.5A max
Please refer to all safety and
installation instructions
and isolate first.
Power only with no alarm circuit
Evaporator Unit (Indoor)
L2
L1
NC
**
Alarm Relay
NC
Alarm Relay
www.condensate-pumps.com / Combi Manual
L1
L2
3
NC
COM
L1
L2
G
**
Alarm Relay
COM
NC
Condensate Pump
Install in accordance with national and regional electrical codes.
If required, install a supplementary fuse on the incoming power rated
T0.2AH250V (T200mAH250V).
(typical) Data
3
L2
L1
Alarm cable not used
COM
Not recommended: water damage can occur if
drain line becomes kinked, pinched or plugged.
COM
Condensate Pump
Condenser Unit (Outdoor)
(typical) Data
3
Ground
Phase 2
L2
100-240 VAC
L1
11
** The Alarm relay Fuse should be rated for application and
of the HRC type
i.e.
for 125V input T6.3AH250V (MAX),
for 250V input T2.5AH250V
Condenser Unit (Outdoor)
3
Ground
Phase 2
L2
100-240 VAC
L1
L2
Utility power
L1
Diagram 2
7

Publicité