LoRaWAN 863-870 PULSE IP68 - Guide utilisateur / User guide V4.0.0
2.
PRODUCT OPERATION
2.1. Global Operation
Important: adeunis® use the most significant byte first format.
The product has several operating modes:
FR
COMMAND
EN
MODE
2.1.1
PARK mode
The product is delivered in PARK mode, it is in standby mode and its consumption is minimal. To switch
the product out of the Park* Mode pass a magnet across it for a duration higher than 6 seconds. The
green LED illuminates to indicate the detection of the magnet and then flashes quickly during the prod-
uct starting phase.
The device then sends its configuration and data frames.
2.1.2
COMMAND mode
This mode allows the user to configure the registers of the product.
To enter this mode, connect a cable to the micro-USB port of the product and enter the command
mode by an AT command.
2.1.3
PRODUCTION mode
This mode allows the user to operate the product in its final use. It should allow a maximum of autono-
my to the product.
2.1.4
Management of the low battery
When the product detects that the battery is not anymore in capacity to deliver the energy needed to
send a frame (extreme temperatures or end-of-life of the battery) it waits to be in capacity to transmit.
If it detects that the delay generated is longer than 1 minute it informs the user via the "battery low"
flag in the status byte of each frame.
Product
should send
a frame
The battery low alarm is switching off if the battery is replaced or when the temperature conditions are
favorable for the proper functioning of the battery.
Command sending
by serial link
Auto adaptation
(cf management
of the low bat-
tery)
yes
Battery is
The product
no
sufficient
is waiting to
to send
be able to
the frame
emit
?
PARK MODE
Presence of a ma-
gnet on the product
>6s
PRODUCTION
MODE
Send "battery low"
flag
OFF (dead bat-
tery)
yes
Delay
no
no
is lower
than 1 min-
ute ?
"Low bat-
The product
no
tery" alarm
sends its
appears in
frame
status byte
Page
44