Vita V
Key:
Key:
Backfeed/Delay
Key:
Standard label
Key:
Field handling
Key:
Key:
Key:
Autoload
Key:
Synchronization at
switching on
Key:
Key:
Key:
Buzzer
Display
100
Device Settings Extended
Backfeed: The backfeed was optimised in the operating mode dispenser. Now, when driving
into the offset, the following label is 'pre-printed' if possible and therefore the backfeed of label is
no necessary and time can be saved.
Delay: The adjustable deceleration time is only for mode Backfeed automatic of importance.
On: If a print order is started without previous definition of label, the standard label is printed.
Off: If a print order is started without previous definition of label, an error message appears in
the display.
Off: The complete print memory is deleted.
Keep graphic: A graphic res. a TrueType font is transferred to the printing system once and
stored in the printing system internal memory. For the following print order only the modified
data is transferred to the printing system. The advantage is the saving of transmitting time for
the graphic data.
The graphic data created by the printing system itself (internal fonts, bar codes, ...) is generated
only if they were changed. The generating time is saved.
Delete graphic: The graphics res. TrueType fonts stored in the internal memory is deleted but
the other fields are kept.
Restore graphic: At the end of the print order the printed order can again be started at the
printing module. All graphics and TrueType fonts are again printed.
NOTICE!
Exception: With column printing always full columns must be printed (number of
pieces always multiple of the columns). Deleted columns are not restored.
Return to previous menu
Start behaviour
On: A label which was loaded once from SD card can be loaded again automatically after a
restart of printer.
The last loaded label from SD card is always again loaded after a restart of printing system.
Off: After a restart of printing system the last used label must be again loaded manually from
the memory card.
A common use of the functions Autoload and Hotstart is not possible.
Off: The synchronization is disabled, i.e. the measuring and label feed have to be released
manually.
Measure: After switching on the printing system, the loaded label is automatically measured.
Label feed: After switching on the printing system the label is synchronised to the beginning of
label. For this one or multiple labels are advanced.
Return to previous menu
User Environment
On: An acoustic signal is audible when pressing a key.
Value range: 1 ... 7.
Off: No signal is audible.
Setting of display contrast.
Value range: 45 ... 75.
English

Publicité