TROUBLESHOOTING
PROBLEM
Air leak near the top of the tool
or in the trigger area
Air leak near the bottom of the tool
Tool does nothing or
operates sluggishly
Tool jams frequently
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
This product has a 90-Day Satisfaction Guarantee Policy, as well as a
For Warranty and Policy details, please go to www.RIDGID.com
POSSIBLE CAUSE
Inadequate lubrication
Loose screws
Worn or damaged O-rings or seals
Inadequate lubrication
Loose screws
Worn or damaged O-rings or bumper
Inadequate air supply
Inadequate lubrication; Possible
debris or buildup slowing delivery of air
through the tool
Worn or damaged O-rings or bumper
Incorrect fasteners
Damaged fasteners
Loose magazine
Dirty magazine
Worn or damaged driver
ILLUSTRATIONS START ON PAGE 13
Three-year Limited Warranty.
or call (toll free) 1-866-539-1710.
12 – English
SOLUTION
Lubricate tool
Tighten screws
Install Overhaul Kit
Lubricate tool
Tighten screws
Install Overhaul Kit
Verify adequate air supply
Lubricate tool
Install Overhaul Kit
Verify that fasteners are the correct
size
Replace fasteners
Tighten screws
Clean magazine
Install Driver Maintenance Kit

Publicité