Glass tube (large)
CAUTION
Secure the connected lead wires of the swing motor and sensor
with a clamp plate. When winding the clamp plate, wrap it with a
resin-coated part so that the wiring does not come into contact with
the edge of the metal plate.
9. When simultaneously installing the wiring refurbishment adapter, refer to the installation guide ([2]-4).
10. When all the work is completed, attach the control box lid of the UV streamer air purifier unit in the reverse
order of the removal procedure.
Attach the control box lid of the indoor unit by inserting the power supply wire side first. (Refer to Figure 23.)
After completing the work, make sure the lid does not come off.
Tighten the screws with a tightening torque of 1.1±0.2 N•m.
WARNING
Attach the control box lid securely by arranging the wires so that none is caught and the control box lid can
be tightly closed. Pinched wires and not tightly closed control box lid may result in electric shock or fire.
17
Lead wire of the swing motor
Tighten so that the connector is
in the centre of the glass tube.
Figure 22
Control box lid
(Indoor unit)
Figure 23
Clamp (2)
(Accessory)
Resin cover
Edge of metal plate
English