8. The pump should only be repaired by qualified technicians or returned to your dealer for
maintenance and repair.
9. You are advised to check the following periodically: The condition of the cables and
grommets, especially at their attachment.
6.2- Repair
Do not attempt to dismantle the pump yourself. If needed, have it inspected and repaired by an
authorized service centre (consult your dealer).
6.3- Troubleshooting
Trouble
Main reasons
Difficult
1. Power voltage too low;
start
2. Impeller clogged
3. Big loss of cable voltage
Weak water
1. Head too high
discharge
2. Strainer and inlet hole clogged
3 Impeller worn badly
4. Submersion too shallow and air
sucked in.
5. Discharge hose disconnected,
leaking or worn out
Sudden stop
1. Switch disconnected or fuse burnt
2. Impeller clogged
3. Stator winding burnt
Stator
1- Run too long with phase lost
winding
2. Winding turn-to-turn short circuit or
burnt
short circuit between phases due to
mechanical seal leakage
3. Impeller clogged
4. Pump started too frequently
5. Pump overloaded
6.4- Storage
Clean the pump.
Pump must be stored in a dry and ventilated location. Always lock up product and keep out of reach
of children.
Disposal
6.5-
- Do not dispose the product with household garbage. Do not throw into the environment.
- Dispose of the product in a collection centre for waste of electrical and electronic equipment, or a
waste drop-off centre; or seek advice from your local municipality.
- Disposal of the product, accessories and packaging should be carried out according to local
regulations governing environment protection.
6.6- Example of installation
See fig.4
Solution
1. Check the power source and make sure it
aligns with the pump power rating.
2. Clean the pump and remove any foreign
matter.
3. Select the proper cable.
1. Use within the rated head range.
2. Clean the pump and remove any foreign
matter.
3. Contact authorized service centre for checking
and repair.
4. Adjust the immersion depth to not less than 0,5
meter.
5. Check hose connection, fix it or replace if
required.
1. check whether the head in use or power
voltage are in compliance with requirements and
adjust accordingly.
2. Clean the pump and remove any foreign
matter.
3. Contact authorized service centre for checking
and repair.
Contact authorized service centre for checking
and repair.