Installation Instructions
ELECTRICAL CONNECTIONS
Model GE02P0BA* water heater is equipped with a factory installed power cord for electrical connection.
Model GE06P0BA* water heater is equipped with a junction box for hard wiring and supplied with an optional
power cord connection.
NOTE: See the page 14 of electrical connections section for details on model GE06P0BA* electrical wiring. The
voltage requirements and wattage load for the water heater are specified on the rating label on the side of the
water heater.
All wiring must conform to local codes or latest edition of National Electrical Code ANSI/NFPA 70.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When using electrical appliances, basic safety precautions to reduce the risk of fire, electric
shock, or injury to persons should be followed, including:
1. Read all instructions before using this water heater.
2. This water heater must be grounded. Connect only to a properly grounded outlet.
3. Install or locate this water heater only in accordance with the provided installation instructions.
4. Use this water heater only for its intended use as described in this manual.
5. Do not use an extension cord set with this water heater. If no receptacle is available adjacent to the water
heater, contact a qualified electrician to have one properly installed.
6. As with any appliance, close supervision is necessary when used by children.
7. Do not operate this water heater if it has a damaged cord or plug, if it is not working properly, or if it has been
damaged or dropped.
8. This water heater should be serviced only by qualified service personnel. Contact the nearest authorized
service facility for examination, repair, or adjustment.
9. Do not use surge protectors or multi-outlet adapters with this water heater.
CAUTION
A damaged power supply cord must be
replaced with one supplied by the unit manufacturer and not
repaired.
WARNING
Proper ground connection is essential.
The presence of water in the piping and water heater does
not provide sufficient conduction for a ground. Nonmetallic
piping, dielectric unions, flexible connections, etc. can cause
water heater to be electrically isolated. Do not disconnect
factory ground.
49-6000248 Rev. 2
2
Factory
Installed
Power Cord