Installation
Installation Warning
NOTICE
For your safety, please read before installation.
Before installing the water heater, please contact
Ÿ
your local gas supplier or gas management
department to select qualified gas pipes,
pressure regulators, clamps, cylinders, exhaust
pipes, etc., must be entrusted to qualified
professional and technical workers to install.
Do not install by yourself, because improper
Ÿ
installation will have a great impact on security
performance, and even endanger the user's life.
Before installation, please reconfirm whether the
Ÿ
type of gas you use is the same as the type of
gas specified on the nameplate of the water
heater.
The water heater is a forced-discharge type
Ÿ
water heater, and the exhaust gas produced by
the water heater must be discharged to the
outdoor atmosphere in strict accordance with
the requirements. It is strictly forbidden to use
this water heater without properly installing the
exhaust pipe according to the requirements of
this instruction.
Shower head
Outlet valve
Water supply pipe(≤2m)
1. Do not install in a place where strong wind can
blow, otherwise the flame of the water heater
will be extinguished or incomplete combustion
will occur.
2. The water heater is forbidden to be installed
outside the house to avoid wind, sun and
freezing of the water heater.
3. The water heater inlet must be connected to the
outside, and the exhaust pipe must be installed.
16
Exhaust pipe
Water heater
Outlet pipe
Inlet pipe
Inlet valve
Air inlet
Gas inlet
wrong
4. It is strictly forbidden to install in the closet.
5. Do not install near flammable materials (such as
curtains, gasoline/organic solvents, etc.) and
corrosive chemicals (such as alcohol) to avoid fire
or corrosion.
6. Do not install the water heater on the vehicle or
on the vessel.
7. There shall be no power line, electrical
equipment or gas pipeline above the installation
position of the water heater. The horizontal
distance between the water heater and the
electrical equipment shall be greater than 40 cm;
gas appliances such as gas ovens and gas stoves
shall not be provided below; and shall not be
close to the induction cooker or microwave oven.
Such as strong electric radiation appliances.
wrong
8. Install the water heater to the surrounding walls
and ceilings at a distance of 150 mm or more. The
installation location should be no. For the
construction of combustible materials, if the
installation site is flammable or flame retardant, it
should be separated by heat-proof plate. The
distance between the heat-proof plate and the
wall should be greater than 10 mm.
wrong
correct
correct
correct