(pipes and hoses), as well as overloading the compressor, will result in pressure
drops.
Permanently laid compressed air pipelines should have an internal diameter of at
least 19 mm and a corresponding large diameter where relatively long pipelines or
multiple users are involved.
Compressed air pipelines should be laid so as to form a gradient (highest point in
the direction to the compressor). Easily accessible water separators should be
installed at the lowest points.
Junctions for users should be joined to the pipelines from above,
Connecting points for fastener driving tools should be fitted with a compressed air
servicing unit(filter/water separator/oiler) directly at the junction point.
Oilers must be checked on a daily basis and if necessary topped up with the
recommended grade of oil (see TECHNICAL DATA). Where hose lengths of over
10 m are used., the oil supply for the fastener driving tool cannot be guaranteed,
We therefore recommend that 2to 5drops (depending on the loading of the
fastener driving tool)of the recommended oil (see TECHNICAL DATA) should be
added via the air inlet of the tool, or an oiler attached directly to the fastener driving
tool. (see fig 5)
4 Preparing the tool for use
4.1 Preparing a tool for first time operation
Please Read and observe these Operating Instruction before using the tool. Basic
safety measures should always be strictly followed to protect against damage to
the equipment and personal injury to the user or other people working in the
vicinity of operation.
- 9 -