4.5
Mount the accessory parts
4.5.1
Fit alarm probe (option, only Mono with float switch)
Alarm probe (art. nos. 20222, 20223)
Screw probe bracket onto pre-assembled adapter.
Clip the probe to the bracket.
Manual diaphragm pump
If required, mount the manual diaphragm pump (art. no. 28680) on one of the connection points on both sides. If neces-
sary, this can be used to pump out the tank contents manually. To this end, cut the required front connection socket to the
required length and mount the manual diaphragm pump.
4.6
Route the mains cables out of the tank
Undo the screws, lift out the components.
Align the rotary discs to match each other (pay attention
to correct order, see coding).
Insert the mains cable(s) into the openings in the sides
and route up to the control unit or the power supply.
Re-install the cable gland and its components in the
reverse order.