Safety
Loading and Unloading/Transporting Management/Storage Requirements
Loading and Unloading Requirements
1) The products shall be carefully handled during loading and unloading.
2) Rude and barbarous handling such as kicking, throwing, dropping, bumping, pulling and rolling is not allowed.
3) The workers engaged in loading and unloading must be subject to necessary trainings on the potential hazards caused
by barbarous handling.
4) Dry powder extinguishers or other suitable fire extinguishing apparatus within the period of validity shall be equipped
at the loading and unloading site.
5) The untrained personnel cannot be engaged in loading and unloading of flammable refrigerants heat pump.
6) Before loading and unloading, anti-static measures shall be taken, and phones cannot be answered during loading
and unloading.
7) Smoking and open fire are not allowed around the heat pump.
Transporting Management Requirements
1) The maximum transporting volume of finished products shall be determined as per local regulations.
2) The vehicles used for transporting shall be operated as per local laws and regulations.
3) Dedicated after-sales vehicles shall be used for maintenance, and exposed transporting of refrigerant
cylinders and the products to be maintained is not allowed.
4) The rain cover or similar shielding material of transporting vehicles shall be provided with certain flame retardancy.
5) Leakage warning device of flammable refrigerant shall be installed inside the closed-type compartment.
6) Anti-static device shall be equipped inside the compartment of transporting vehicles.
7) Dry powder extinguishers or other suitable fire extinguishing apparatus within the period of validity shall be equipped
inside the driver's cab.
8) Orange-white or red-white reflective stripes shall be pasted on the sides and tail of the transporting vehicles, to remind
the vehicles behind of keeping distance.
9) The transporting vehicles shall run at a constant speed, and heavy acceleration/deceleration shall be avoided.
10) Combustibles or the static articles cannot be transported simultaneously.
11) High-temperature area shall be avoided during transporting, and necessary radiating measures shall be taken in case
the temperature inside the compartment is too high.
Storage Requirements
1) The storage package of equipment used shall be such that no leakage of refrigerant will be caused due to mechanical
damage of the equipment inside.
2) The appliance must be stored in a room without continuously operating ignition sources, the radius of the storage area
should be no less than 2.5 m (for example:open flames, an operating gas appliance or an operating electric heater).
3) Do not pierce or burn.
4) The maximum quantity of the equipment allowed to be stored together shall be determined as per local regulations.
Safety Awarenes
1.Procedures: operation shall be made as per controlled procedures to minimize the probability of risks.
2.Area: area shall be divided and isolated appropriately, and operation in an enclosed space shall be avoided. Before the
refrigeration system is started or before working, ventilation or opening of the area shall be guaranteed.
3.Site inspection: the refrigerant shall be checked.
4.Fire control: the fire extinguisher shall be placed nearby, and fire source or high temperature is not allowed; the sign of
"No smoking"shall be arranged.