Télécharger Imprimer la page

Ribimex PE200/400T Manuel D'instructions Et D'utilisation page 14

Palan électrique telecommande

Publicité

- Please ensure to check the units which are easy to worn out mentioned above and you should
change them each half year, to ensure the safety of the operator and the machine.
- Periodically check if the steel cable is in good conditions.
Note: Abrasion of the steel cable
Check abrasion of the steel cable, if the wear/abrasion area exceeds 10% of
the original size; replace the steel cable with a new one.
- Check if the screws securing the brackets and reduction gear are tight well.
- Check if the conditions and tightening of the nuts securing the steel cable
clamps.
- Periodically check if all the switches (e.g. motor cut-off switch, push button
switch) are in good operating conditions
TECHNICAL DATA
Reference
Technical
information
Load capacity
Lifting height
Lifting speed
Cable length
Cable diameter
Cable resistance
Service
Main voltage
Motor performance
Rem: These descriptions and illustrations are not binding. We reserve the right to modify them and the
technical data without prior notice.
Environment
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or retailer for recycling
advice.
OPERATION STEPS
- Insert the Battery of AA type with full power in the trasmitter.
- Turn the Knob Key Switch to ON and press START Button for 5 seconds to start the remote
control (Automatic shutdown without action within 10 minutes).
- Operate the trasmitter on the buttons function.
- Handling after operation:
(1) Press emergency button.
(2) Turn off the Key switch and pull it out.
- Take out the batteries if it would be not used for long time.
TROUBLESHOOTING
- The trasmitter is with two alkaline AA batteries.
- The LED indicator flash green after pressing the button if the batteries are full electric.
- Otherwise the LED indicator flash red or does not flash if the electric is not enough. Then the
batteries should be changed soon.
- TX LED remains ON with red light. Solution: Please remove the batteries and insert again.
- The RX does not respond at all. Solution: Turn the main power off for 20 Seconds and turn it on
again.
CODING METHOD
PE200/400T
Standard version
Version with double
200kg
18m
10m/min
18.5 m
3.8 mm
≥ 1100kg
S3 20%-10 min
230V~50Hz
P1 950W
Standard version
load
400kg
9m
5m/min
10m/min
PE400/800T
Version with
double load
400kg
800kg
18m
9m
5m/min
18.5 m
5,1 mm
≥ 2000kg
S3 20%-10 min
230V~50Hz
P1 1350W

Publicité

loading

Ce manuel est également adapté pour:

Pe400/800t