Daikin ARXTM30A2V1B Manuel D'installation page 9

Publicité

3
About the box
3.1
Outdoor unit
3.1.1
To handle the outdoor unit
CAUTION
To avoid injury, do NOT touch the air inlet or aluminium
fins of the unit.
Only handle the outdoor unit as follows:
a
b
a
Drain socket
b
Accessory bag
Make sure the unit is placed on a flat surface to avoid damage.
3.1.2
To remove the accessories from the
outdoor unit
Make sure you have all following accessories delivered with the unit:
a
b
c
a
General safety precautions
b
Outdoor unit installation manual
c
Fluorinated greenhouse gases label
d
Multilingual fluorinated greenhouse gases label
e
Energy label
f
Drain socket (located separately on the bottom of the
packing case)
g
Sealing for drain socket
RXTJ-A, RXTA-C, RXTM-A, RXTP-A, ARXTM-A
R32 split series
3P600450-11Y – 2024.04
d
e
f
g
4
Unit installation
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
4.1
Preparing the installation site
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
4.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
b
>100
a
>50
b
>150
a
>50
(mm)
a
Air outlet
b
Air inlet
NOTICE
The height of the wall on the outlet side of the outdoor unit
MUST be ≤1200 mm.
Do NOT install the unit in sound sensitive areas (e.g. near a
bedroom), so that the operation noise will cause no trouble.
Note: If the sound is measured under actual installation conditions,
the measured value might be higher than the sound pressure level
mentioned in "Sound spectrum" in the data book due to
environmental noise and sound reflections.
INFORMATION
The sound pressure level is less than 70 dBA.
The outdoor unit is designed for outdoor installation only, and for
ambient temperatures within the following ranges:
Cooling mode
–10~46°C DB
4.1.2
Additional installation site requirements
of the outdoor unit in cold climates
Protect the outdoor unit against direct snowfall and take care that the
outdoor unit is NEVER snowed up.
3 About the box
a
>150
b
>50
b
>100
a
a
>100
b
Heating mode
–30~24°C DB
Installation manual
9