GB - GENERAL ELECTRICAL CONNECTION
ATTENTION
THE INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN COMPLIANCE WITH IEC STANDARDS, LEGAL PROVISIONS AND SPECIFICA-
TIONS NATIONAL RULES ON ELECTRICAL AND HYDRAULIC INSTALLATIONS. THE INSTALLER BEFORE MAKING CONNECTIONS OF THE APPLIANCE-
TURA MUST REQUEST THE DECLARATION OF CONFORMITY OF PLUMBING AND ELECTRICAL SYSTEMS, REQUIRED BY LAW
THIS DOCUMENTATION THE COMPANY SAUNA VITA S.R.L. IS EXEMPT FROM ANY RESPONSIBILITY FOR PREMISES AND SYSTEMS, WHERE IT WILL BE
INSTALLED YOUR OWN EQUIPMENT.
WARNING
IN CASE OF NON-COMPLIANCE, EVEN PARTIAL, WITH THE SAFETY CONDITIONS, BOTH THE WARRANTY AND THE RESPONSIBILITY FOR THE
INABILITY OF THE MANUFACTURER FOR ANY DAMAGE OR INDIRECT CAUSED BY THE PRODUCT. THE FORFEITURE OF THE GUARANTEE, IN THE HYPO-
THESIS INDICATED ABOVE WILL HAVE AS CONSEQUENCES THE REPLACEMENT ONLY OF THE PIECES THAT WILL BE RECOGNIZED AS DEFECTIVE,
WITHOUT COVER THE COSTS DERIVED FROM THE LABOR REQUIRED TO REMOVE THE PRODUCT.
TECHNICAL DATA
ELECTRICAL CHARACTERISTICS
MODEL
Resistences
4 kW
2 x 2000 W
400-3N
6 kW
3 x 2000 W
400-3N
9 kW
3 x 3000 W
400-3N
12 kW
3 x 4000 W
400-3N
*
See page 6.
DIMENSIONS
66 cm
53 cm
ELELECTRICAL SAFETY NOTE:
The products are manufactured in compliance with 60335.2.105. They are tested to ensure the safety of the user, installation of such equipment
it must be carried out by qualified personnel, in compliance with IEC standards and national regulations in force in each country. The installer must also
be authorised to issue an attestation of conformity of a correct installation. It must demand from the user, (before installation of the appliance) the declaration
of conformity of the installations of the building required by law. In the absence of such documentation, the Company declines any responsibility for the
facilities or premises where the product will be installed. The products must be permanently fixed and connected in a fixed mannerto the earthing plant. Ensure
that the earthing system is efficient (refer to standard 64.8). The installation must be carried out by qualified and qualified personnel, both as regards the
electrical and hydraulic connection. Before proceeding with the connection, the installer must ensure that the electrical system complies with CEI 64.8 stan-
dards, protected by a residual current circuit breaker 0.03A, and that the earthing system is efficient and complies with the provisions mentioned above.
necessary to incorporate into the power supply network a disconnection device with a contact opening distance that allows complete disconnection under the
conditions of category of overvoltage III, in accordance with the installation rules.
opening of the contacts of at least 3 mm, and placed outside the safety zones as required by the technical standard CEI 64-8/7 latest edition (it must be
installed in areas not reachable by the user who is using the equipment) away from possible splashes or water supplies (see drawing). The cable for
the connection to the electrical system must be protected by a corrugated pipe that must not have intermediate joints or connections. The cable must not
have characteristics inferior to type H05VV-F its section must be sized according to the model. The components used for the connection must
have characteristics and IP protection degree as required by 64.8 standards for applications in bathrooms and showers.
RECEIVING GOODS:
Check upon receipt of the goods the conditions of the packaging and the product, especially if the packaging has visual damage, point it out directly to the transporter.
The manufacturer declines all responsibility for transport.
GENERAL WARNINGS:
A - Install the steam pipe without interposing siphons to prevent condensation water from remaining in the pipeline itself, generating, inter alia, hygiene issues.
It is recommended to use copper or steel tubes with a maximum length of 5000 mm.
B - Insulate the steam pipes well.
C - Install the steam generator in a dry and well-ventilated environment. Install it indoors to avoid freezing in winter.
D - Access to the steam generator must not be obstructed to facilitate maintenance.
E - If the water pressure is higher than indicated, install pressure reducers.
F - Provide stop taps out of the bulk of the product for closing hot and cold water.
GRUPPO GEROMIN S.r.l. reserves the right to make changes to the product at any time without giving any notice.
V
A
kW
Hz
Fuses
230
16
4
50
1 x 25 A
10
4
50
2 x 16 A
230
30
6
50
1 x 32 A
10
6
50
3 x 16 A
230
45
9
50
1 x 50 A
15
9
50
3 x 20 A
230
60
12
50
1 x 63 A
20
12
50
3 x 25 A
H.50 cm
Net weight: 16Kg Gross weight: 23Kg
Volume
Outlet diameter
N° Dispen-
steam (mm)*
sers
1 piece
Ø 28
(3/4" connec-
tion)
1 piece
Ø 28
(1" connec-
tion)
1 piece
Ø 28
(1" connec-
tion)
2 pieces
Ø 32
12 ÷ 16
(1" connec-
tion)
The connection to the mains must be done through an omnipolar switch with
20
.
IN THE ABSENCE OF
Production
Water supply
idle
steam
pressure (bar)
(m
)
(Kg/h)
3
MIN150kPa (1,5 bar)
0 ÷ 6
8
MAX300kPa (3,0 bar)
MIN150kPa (1,5 bar)
6 ÷ 9
12
MAX300kPa (3,0 bar)
MIN150kPa (1,5 bar)
9 ÷ 12
19
MAX300kPa (3,0 bar)
MIN150kPa (1,5 bar)
24
MAX300kPa (3,0 bar)
Grades
of
protection
IP20
IP20
IP20
IP20
It is