5.4 Simplex/half-duplex settings
Position 7 of the SW2 DIP switch is used for the communication setting.
5.5 Terminating resistor setting
Position 8 of the SW2 DIP switch is used for the terminating resistor setting.
6. Alarm IN/OUT

6.1 Circuit diagram

DC Load
OUT(n)
Dome
+
-
DC
Relay Output
OUT(n)
Diagram (left)
Circuit diagram left:
Consumers can be connected with the following load here.
DC: Max. 12 V DC, 30 mA
Schaltplan Right::
An external relay must be used to prevent electrical damage to the dome.
SW2 DIP switch simplex/half-duplex settings
Description
Position 7 settings
ON
Simplex
SW2
1
ON
Half-duplex
SW2
1
SW2 DIP switch terminating resistor settings
Description
Position 8 settings
ON
No
SW2
1
ON
Yes
SW2
1
GND OUT
12VDC
30mA
OUT(n)
Dome
Relay Output
OUT(n)
Diagram(right)
42
7
OFF
2
3
4
5
6
7
8
ON
2
3
4
5
6
7
8
8
OFF
2
3
4
5
6
7
8
ON
2
3
4
5
6
7
8
JQC- 3FG
Relay
(10 A 250VAC)
English
~220V AC
L
N