Installation manual
3.
INSTALLATION
3.1.
Spa location and installation
Determine the location of the filtering, heating and massage equipment.
Determine the location of the pipes' exit.
Place the equipment near the Spa. The maximum distance between the equipment and the Spa
is 7 metres. If these measures cannot be adopted consult your provider.
ATTENTION – These maximum distances are those covered by the connection pipes
between the equipment and the Spa.
The Compact equipment must be placed under the Spa level in order not to prime the pumps.
The maximum level difference is 1 metre above the Spa and 2 metres below.
Avoid any location where water may enter the electric equipment compartment.
Free space should be left if maintenance work is required.
3.2.
Compact equipment and Spa assembly.
The following type of pipes must be used for the connection:
Filtering circuit:
Massage circuit (jets):
Massage air circuit:
*In standard distances (maximum 7 m) and without loading loss excess.
Follow the following schemes and instructions to assembly each circuit.
At any case bend and pipe installation should be minimized in order to reduce the installation
loading loss.
PN 10 diametre 50 mm*.
PN 10 diametre 50 mm*.
PN 10 diametre 50 mm*.
8
English