Télécharger Imprimer la page

Bosch B36CL80ENS/07 Notice De Montage Et D'utilisation page 13

Publicité

Before using for the first time
Remove information material, adhesive tape and
1.
protective foil.
Remove the power cord from inside the
2.
appliance.
Clean the appliance.
3.
~ "Cleaning" on page 28
Install the equipment.
4.
~ "Equipment" on page 16
Water connection
9
CAUTION
Never bend, crush, modify or cut water hoses.
Never pull on the water hose on the rear panel
of the appliance.
To avoid damaging the appliance and to
ensure proper functioning, it should only be
connected to a drinking water line.
To avoid water damage, a shut-off valve must
be installed.
Notes
Installation and connection of the appliance must
be carried out by a qualified technician.
The shut-off valve must also be freely accessible
following installation of the appliance.
Observe the local regulations for water
connection.
The water quality of the water connection is tested:
Rinse the water line leading to the appliance
thoroughly until there are no more sediments or
turbidity in the water.
If the water line leading to the appliance still
contains sediments or turbidity, install an external
water filter system.
Water pressure of drinking water line
9
CAUTION
To avoid damage to the appliance, a pressure
relief valve must be installed between the
drinking water connection and the hose set if
the water pressure exceeds the maximum
value.
If the water pressure is too low, this will impair
Note:
functioning of the appliance.
Water pressure min.: 0.2 MPa (2 bar / 29 psi)
Water pressure max.: 0.8 MPa (8 bar / 116 psi)
Installation and connection en-us
Electrical connection
9
CAUTION
Do not connect the appliance to electronic
energy saver plugs.
You can connect the appliance to mains-
Note:
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national
grid. Sine-controlled inverters must be used for
isolated applications. Isolated applications, e.g. on
ships or in mountain lodges, are not directly
connected to the national grid.
Insert the power cord plug in the rear of the
1.
appliance.
Check that the power outlet has been installed
2.
according to the regulations and complies with
the requirements.
Requirements for power outlets
Power outlet with grounding
conductor:
Circuit breaker:
Maximum load
Appliance:
Connect the appliance to an outlet near the
3.
appliance.
The outlet must also be freely accessible
following installation of the appliance.
If free access is impossible, an all-pole isolating
switch must be integrated into the permanent
electrical installation according to the installation
regulations.
9
WARNING
RISK OF ELECTRIC SHOCK!
Never use multiple outlets, extension cords
or adapters.
The appliance must be grounded correctly.
Never cut through or remove the power
cord's third conductor (grounding
conductor).
9
WARNING
RISK OF ELECTRIC SHOCK!
If the power cord is too short, never use
multiple outlets or extension cords. Instead,
please contact customer service.
110 V ... 127 V /
60 Hz
min. 15 A ... 20 A
5.5 A
13

Publicité

loading

Ce manuel est également adapté pour:

B36cl80ensB36cl en serieB36cl80sns